                                | Type | Lead Acid Battery Pack | 
| Voltage | 12V | 
| Power | 80Ah | 
| Certificate | UN38.3, UL, SGS, CE, PB | 
| Lead Time | 10 Days | 
| Payment | T/T, L/C,Western Union | 
| Warranty | 5 Years | 

Presenting the 12V 80AH sealed valve-regulated lead-acid battery,
a robust energy solution designed for diverse applications.
Key Features:
Applications:
 




If you need any help with series, parallel or series-parallel battery configurations, please contact us!

Tags:
1. Specifications
| Nominal Voltage | 12V | |
| Rated capacity (10 hour rate) | 80Ah | |
| 
 
 Dimensions | Length | 330±2mm(12.99inch) | 
| 
 | Width | 171±2mm(6.73inch) | 
| 
 | Height | 214±2mm(8.43inch) | 
| 
 | Total Height | 220±2mm(8.66inch) | 
| Approx. Weight | 22.6kg(49.72lbs)±3% | |
2. Characteristics
| Capacity (25℃) | 10HR(10.8V) | 80Ah | |
| 
 | 3HR(10.8V) | 60Ah | |
| 
 | 1HR(10.5V) | 40Ah | |
| Terminal type | T16 | ||
| Internal resistance (Fully charged,25℃) | Approx.4.5m Ω | ||
| Capacity affected by temperature (10HR) | 40℃ | 102% | |
| 
 | 25℃ | 100% | |
| 
 | 0℃ | 85% | |
| 
 | -15℃ | 65% | |
| 
 Self-discharge (25℃) | 3 months | Remaining Capacity:91% | |
| 
 | 6 months | Remaining Capacity:82% | |
| 
 | 12 months | Remaining Capacity:65% | |
| Nominal operating temperature | 25℃±3℃(77℉±5℉) | ||
| Operating temperature range | Discharge | -15℃~50℃(5℉~122℉) | |
| 
 | Charge | -10℃~50℃(14℉~122℉) | |
| 
 | Storage | -20℃~50℃(-4℉~122℉) | |
| 
 Float charging voltage(25℃) | 13.50 to 13.80V Temperature compensation: -18mV/℃ | ||
| 
 Cyclic charging voltage(25℃) | 14.50 to 15.00V Temperature compensation: -30mV/℃ | ||
| Maximum charging current | 30A | ||
| Maximum discharge current | 600A(5 sec.) | ||
| Designed floating life(20℃) | 10years | ||
3. Outer dimensions (mm)

4. Terminal Type (mm)

5. Construction
| Component | Positive plate | Negative plate | Container | Cover | Separator | Electrolyte | Safety valve | Terminal | 
| Raw material | Lead dioxide | Lead | ABS | ABS | AGM | Sulfuric acid | Rubber | Copper | 
6. Constant Current Discharge Characteristics Unit:A(25℃,77℉)
| F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h | 
| 9.60V | 218 | 168 | 101 | 61.8 | 36.5 | 26.3 | 21.0 | 18.0 | 12.3 | 10.2 | 5.40 | 
| 9.90V | 211 | 164 | 98.5 | 60.9 | 36.3 | 26.2 | 20.9 | 17.8 | 12.3 | 10.2 | 5.38 | 
| 10.2V | 203 | 158 | 95.5 | 59.3 | 36.0 | 26.0 | 20.7 | 17.7 | 12.2 | 10.1 | 5.37 | 
| 10.5V | 194 | 153 | 93.2 | 57.5 | 35.5 | 25.8 | 20.6 | 17.6 | 12.1 | 10.1 | 5.34 | 
| 10.8V | 183 | 144 | 89.7 | 55.6 | 34.6 | 25.0 | 20.0 | 17.1 | 11.7 | 10.0 | 5.30 | 
7. Constant Power Discharge Characteristics Unit:W(25℃,77℉)
| F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h | 
| 9.60V | 2354 | 1845 | 1128 | 705 | 423 | 309 | 247 | 212 | 147 | 122 | 64.7 | 
| 9.90V | 2284 | 1800 | 1105 | 694 | 421 | 308 | 246 | 211 | 146 | 121 | 64.6 | 
| 10.2V | 2190 | 1734 | 1071 | 676 | 417 | 306 | 244 | 209 | 145 | 121 | 64.4 | 
| 10.5V | 2095 | 1675 | 1045 | 655 | 411 | 303 | 242 | 208 | 144 | 120 | 64.0 | 
| 10.8V | 1978 | 1586 | 1007 | 634 | 400 | 294 | 235 | 202 | 139 | 119 | 63.6 | 
Note: The above characteristics data can be obtained within three charge or discharge cycles.
7. 12v 80ah lead-acid battery pack charge discharge diagram