• High cycle life
4000 cycles @80% DoD for effectively lower total of ownership cost
• Longer service life
Low maintenance batteries with stable chemistry.
• Built in circuit protection
Battery Management System (BMS) is incorporated against abuse.
• Better storage
up to 6 months thanks to its extremely low self 
discharge (LSD) rate and no risk of sulphation.
• Quickly recharge
Save time and increase productivity with less down 
time thanks to superior charge/discharge efficiency.
• Extreme heat tolerance
Suitable for use in a wider range of applications where 
ambient temperature is unusually high: up to +60°C.
• Lightweight
Lithium batteries provide more Wh/Kg while also 
being up to 1/3 the weight of its SLA equivalent.










Tags:
ELECTRICAL PERFORMANCE
| 
			 Nominal Voltage  | 
			
			 48V  | 
		
| 
			 Nominal Capacity  | 
			
			 200 Ah  | 
		
| 
			 Capacity @ 20A  | 
			
			 300 min  | 
		
| Energy | 10240 Wh | 
| Communication | CAN2.0/RS232/RS485 | 
| Resistance | ≤45 mΩ @ 50% SOC | 
| 
			 Efficiency  | 
			>96% | 
| Module Parallel | 
			 Up to 3 packs  | 
		
CHARGE PERFORMANCE
| 
			 Recommended Charge Current  | 
			
			 20A  | 
		
| 
			 Maximum Charge Current  | 
			
			 100A  | 
		
| 
			 Recommended Charge Voltage  | 
			
			 57.6V  | 
		
| 
			 BMS Charge Cut-Off Voltage  | 
			
			 <58.4 V (3.65V/Cell)  | 
		
| 
			 Reconnect Voltage  | 
			
			 >57.6 V (3.6V/Cell)  | 
		
| 
			 Balancing Voltage  | 
			
			 <57.6 V (3.6V/Cell)  | 
		
| 
			 Maximum Batteries in Series  | 
			
			 16 (*Consult Neexgent)  | 
		
MECHANICAL PERFORMANCE
| 
			 Dimension (L x W x H)  | 
			
			 580 x 420 x 230mm 22.8” x 16.54” x 9.06”  | 
		
| 
			 Approx. Weight  | 
			
			 97lbs (44kgs)  | 
		
| 
			 Terminal Type  | 
			
			 DIN POST  | 
		
| 
			 Terminal Torque  | 
			
			 80 ~ 100 in-lbs (9 ~ 11 N-m)  | 
		
| 
			 Case Material  | 
			
			 METAL  | 
		
| 
			 Enclosure Protection  | 
			
			 IP65  | 
		
DISCHARGE PERFORMANCE
| 
			 Maximum Continuous Discharge Current  | 
			
			 100 A  | 
		
| 
			 Peak Discharge Current  | 
			
			 110 A (3s)  | 
		
| 
			 BMS Discharge Cut-Off Current  | 
			
			 150 A (300ms)  | 
		
| 
			 Balancing open voltage  | 
			
			 55.2V (3.45V/Cell)  | 
		
| 
			 Recommended Low Voltage Disconnect  | 
			
			 44 V (2.75V/Cell)  | 
		
| 
			 BMS Discharge Cut-Off Voltage  | 
			
			 >32.0V (2s) (2.0V/Cell)  | 
		
| 
			 Reconnect Voltage  | 
			
			 >40.0 V (2.5V/Cell)  | 
		
| 
			 Short Circuit Protection  | 
			
			 250 ~ 500 μs  | 
		
TEMPERATURE PERFORMANCE
| 
			 Discharge Temperature  | 
			
			 -4 ~ 131 ºF (-20 ~ 55 ºC)  | 
		
| 
			 Charge Temperature  | 
			
			 -4 ~ 113 ºF (0 ~ 45 ºC)  | 
		
| 
			 Storage Temperature  | 
			
			 23 ~ 95 ºF (-5 ~ 35 ºC)  | 
		
| 
			 BMS High Temperature Cut-Off  | 
			
			 149 ºF (65 ºC)  | 
		
| 
			 Reconnect Temperature  | 
			
			 131 ºF (55 ºC)  | 
		
HEATING FOIL PERFORMANCE
| 
			 Heating Temperature Range  | 
			
			 -4 to 41 ºF (-20 to 5 ºC)  | 
		
| 
			 Heating Time  | 
			
			 Approximately 1 hour @ 7.5 A  | 
		
| 
			 BMS Heating Foil Cut-Off  | 
			
			 158 ºF (70 ºC)  | 
		
OUTLINE DIMENSION

| 
			 L mm(”)  | 
			
			 W mm(”)  | 
			
			 H mm(”)  | 
		
| 
			 580(22.8)  | 
			
			 420 (16.54)  | 
			
			 230 (9.06)  | 
		

APPLICATIONS
Lithium Iron Phosphate can be used in most applications that use 
Lead Acid, GEL or AGM type batteries.
Suitable applications include:
• Solar Storage
• Switching applications and more
• Base transceiver station
• Communication equipments
• Central office
• Telecommunication systems
• Electronic cash registers
• Microprocessor based office machine
• UPS